The WK-10W spindle limit switch is designed for use in AC and DC auxiliary circuits, as well as in main current motor o-circuits.
They are used to reduce:
– The highest permitted positions of the crane’s hook sling,
– The lowest permissible positions of the hook sling in cases where it is lowered
into a space not visible by the crane (e.g., under the floor or working level),
– The final positions of other machines and equipment.
Basic technical data
Type of switch |
Unit. |
WK-12W-1 | WK-12W-2..8 | ||
Rated insulation voltage Ui |
[V] |
500 |
|||
Rated switching voltage Ue |
[V] |
500V, 50Hz |
|||
Rated continuous current |
[A] |
63 |
40 |
||
Rated switchable current Ie for U=380V for U=500V |
[A] |
50 |
25 |
||
Rated switching frequency |
[min-1] |
2 |
4 |
||
Switching life |
[joints]. |
5 x 104 |
105 |
||
Number of current paths |
4 |
8 |
|||
Mechanical durability |
[cykli] |
0,3 x 106 |
|||
Mass |
[kg] |
8,8 |
|||
Degree of protection |
IP-54 |